Worcester Bosch ignition lockout
This is a video of a Worcester Bosch Greenstar Junior/Si boiler with ignition lockout.
Worcester Bosch Greenstar Junior and Si boilers don’t show a conventional “fault code” when they have an issue, the front display lights flash in a certain sequence to indicate a fault .
This can make it harder for homeowners and even engineers to understand what is wrong with the boiler.
Ignition lockout on a Worcester Bosch boiler means that the burner has failed to ignite and the boiler has shut down.
Ignition lockout is the most common fault on Worcester Bosch boilers, when Greenstar Junior/Si boilers go to ignition lockout the display lights flash in the following sequence;
The reset light flashes continuously and the blue oval light at the bottom of the display is mostly off and exhibits a slow flash every few seconds.
If you look in the installation manual it states the following;
Gas present and at correct pressure?
• Gas valve – Check that there is approximately 27V d.c. to each solenoid – Check the resistance of each solenoid: Top solenoid = 380 S + 10% (342 – 418 S) Bottom solenoid = 190 2 10% (171 – 209 2)
• Combustion CO2 level. • Flue condition. – Blocked flue? • Blocked condensate pipe or frozen condensate.
• Gas valve adjustment.
• Ignition electrodes/harness/connections. – Check for condition and resistance of leads (approximately 2100 S2)
• Otherwise replace control
If you are an end user you can check the following;
1) You have no issues with the gas supply.
2) Ensure that you have no issues with an external frozen condensate pipe. Aside from that you will have to call a heating industry professional to have a look at your boiler.
The benefits of using us to repair your Worcester Bosch boiler.
Local engineers on time
You know when you call us that you’re going to get a local, experienced, Gas Safe registered heating engineer, with experience working on Worcester Bosch boilers, who turns up if they have promised to do so.
12 Month guarantee
To provide you with the best possible service and peace of mind, we always provide a 12 month guarantee on any parts fitted to your Worcester Bosch boiler or central heating system.
What our customers say about us…
Neil was quick to reply to my enquiry, arranged an appointment to come really quickly and came at the time he said. He had all the parts required to fix my boiler the same day. Really thorough checking everything over and worked cleanly. Would highly recommend and will definitely use him in the future.
Sarah
Superb service – Neil came out to my property within a few days of contacting him, diagnosed the boiler fault and was able to fix it the same day with new parts, all for a reasonable price.
Helen
Need an urgent Worcester Bosch boiler repair in Sheffield, Barnsley or Rotherham?
Thanks to our extensive professional experience and all the boiler spares we carry, we are the best choice when it comes to a Worcester Bosch boiler repair.
Aside from offering a great price on boiler repairs, we also offer a 12 month guarantee on any parts fitted to your Worcester Bosch boiler.
Call for Service Today
07881524941
Recent Blog Posts
Glowworm Flexicom cx noisy pump
View Article
Worcester Bosch Greenstar 8000 2924 fault code
View Article